blog NIT

VAŠ VODIČ ZA PAMETNE ODLUKE

blog NIT - VAŠ VODIČ ZA PAMETNE ODLUKE

Medical Devices Software.

 

Saznajte uzrok vaših problema

Primer usporenog metabolizma

Srpska verzija

Hardware and software package  is designed for determination and evaluation of the functional condition of human organism without invasion into internal environment.

Possibilities of hardware and software diagnostic complex

  • advanced and detailed control of all organs and systems within 30 minutes;
  • ability to conduct diagnostics of ALL organs and systems of patients of any age;
  • high sensibility of determination of functional deviations even at INITIAL stage of their development;
  • detection of type of toxic exposure: parasitic, bacterial, viral or chemical (both endogenous and exogenous);
  • prognostic estimation of disorders in the course of time;
  • control of therapeutic action intensity and influence of ANY OTHER exogenous factors (psychoemotional, meteorological, pharmacotherapeutic, physiotherapeutic etc.);
  • possibility of FAST and the MOST ADEQUATE correction of discovered deviations by means of natural agents (herbal remedies, biologically active nutritional additives, homeopathic agents etc.);
  • allows to apply a COMPLEX APPROACH in treatment of after-effects of stress and consequences of acute and chronic conditions;
  • INDIVIDUAL SELECTION of necessary modes of therapeutic and corrective actions;
  • HIGH ACCURACY AND CONVENIENCE FOR PATIENT;
  • IS NOT DIFFICULT AND PAINLESS FOR PATIENT;
  • ability to accumulate data about patient’s condition with further design of OPTIMAL MODE of treatment and prevention of various diseases.

Novelty and distinctive features of HSDC «Intera»

Hardware and software diagnostic complex (HSDC) “Intera-” simultaneously registers a constellation of various electrophysiological parameters of skin areas that at different topographic levels are connected via reflex with spinal cord segments (neck, thoracal, lumbosacral) and nerve plexus by means of which nervous (sympathetic and parasympathetic) regulation of organs is performed. As distinct from other electropucture methods, indicators registered by HSDC “Intera” reflecting condition of skin areas don’t depend on idiomotoric reactions of operating doctor who can subjectively influence the pressure of measurement electrode and consequently alter the reliability of the obtained results. HSDC “Intera” provides constant contact of electrodes with patient’s skin and it is steadily controlled during diagnostic process. This allows paramedical personnel to conduct the measurement.

Analysis of conductivity indicators (expressed by curves) of forehead, palms and feet skin areas depending on lability of central and vegetative nervous system discovers individual psychophysiological characteristics of patient and his reaction to various environmental factors that is particularly necessary for testing of people engaged in operating activity such as drivers, pilots, sportsmen etc. Programmed measuring modes and algorithms for 30 leads allow to detect an “individual skin code” (conductivity values of different topographic skin areas) that depends on peculiarities of vegetative hormone regulation and functional condition of organs.

Pic.1. Individual skin code and electrophysiological values of forehead, palms and feet skin areas

“Skin code” parameters together with summation of certain leads and individual psychophysiological features of patient represent the condition of central and vegetative nervous system at different topographic levels as well as functional condition of organs that are interconnected with certain receptor skin areas.


Pic. 2. Electrophysiological characteristics of pancreas condition

Analysis of conductivity indicators in view of direct current makes possible an indirect estimation of summary biophysical characteristics of individual organs and systems at cell level in their functional unity together with indicators of the entire organism.


Pic. 3. Biophysical parameters of functional condition of gall-bladder against the background of indicators characterizing condition of the entire organism

Biophysical characteristics underlying the designed criteria of estimation of the organs condition, such as “summary membrane potential”, “summary receptor sensitivity”, “receptivity”, “reactivity”, “alteration”, “demobilization”, “intoxication” allow to extend a conception about pathophysiological processes at cell level.

Additional registration of electrophysiological values regarding biologically active points of head that reflect processes of neurohumoral regulation (measurement projection of hypothalamus-hypophysis) extends the range of informational indicators. At the same time there is an increased possibility to register special rapid declination curves (RDC) of the current. Taking into consideration summary biophysical parameters of cells it allows to estimate the extent of organ disturbance as a result of toxic exposure to organism: parasitic, bacterial, viral or chemical (both endogenous and exogenous).

Pic. 4. Diagram reflecting condition of spinal cord and estimation of the internal organs condition

For diagnostics of spinal cord condition we use a “cutoff” time mode while conducting prolonged measurement of each lead (no less than 2-3 seconds). Asymmetry of obtained values regarding spinal column and increased height of grey colored columns is an evidence of vertebras dislocation and decrease of height of intervertebral discs.

Programmed prognostication of pathologic processes development detects deviations of different organs and systems at the moment of diagnostic procedure ranging from first signs of inflammation in the past up to functional insufficiency in the present or future. For each patient individually according to obtained diagnostic results percent efficiency of recommended medicines is assessed: “Corr” – drugs of general action and “Dev” – drugs of specific action, accompanied by detailed information about the drugs with according serial number assigned (pic. 6).


Pic. 5. In-Yan

Combination of HSDC “Intera” and R. Voll diagnostic criteria significantly increases efficiency of the least owing to possibility of purposeful search of measurement points in projective skin areas with critical deviations represented by increased or decreased conductivity (pic. 5 In-Yan). The idea of HSDC “Intera” combines the approaches of alternative (Tibetan, Chinese) and academic medicine with purpose of systemic evaluation of health condition, thus enhancing the effectiveness of choice of remedies for treatment and prevention of various diseases.


Pic. 6. Scanning

Comparison of HSDC “Intera” that characterizes functional condition of organs and results obtained by means of physical and laboratory examinations aimed to form a diagnosis demonstrate compliance of deviations (near 90 %) that gives a possibility to widen characteristics of pathological disorders.

Hardware and software package «Intera» is designed for determination and evaluation of the functional condition of human organism.

Computerized diagnostics of human health condition is based on registration of parameters of zonal conductivity under conditions of the direct current from different body areas and receptor zones that are functionally associated with certain internal organs.

To the appointed skin areas (forehead, hands and feet) by a contact method there are applied six electrodes by means of which an electric signal of low intensity is recorded. Recording of electrical patterns under conditions of the direct current is consecutively conducted in 30 vector directions in the mode of multiple repetitive recordings that allows statistically average the parameters of measurement during the process of diagnostics in order to receive reliable figures (mode of scrolling).

In our package, in contrast to electrocardiography, encephalography or myography there is fixed not an alternating current of high frequency (such as “action potential”), the summarized registration of which is executed by these methods, but the conductivity of the direct current between various pairs of electrodes. (!)This allows to estimate the qualitative summarized values of “membranous potentials” and response of cell receptors of various organs to effects of external environment that reflects their functional condition on a cellular level (pic. 3 – 5). At the same time there is defined a dominant type of vegetative regulation on various levels: sympathetic or parasympathetic (in the mode of vegetative test) as well as vegetative reactions lability (calibration mode).

pic.3 pic.4 pic.5

One of the main tasks of the presented methodic of functional diagnostics is (!) the estimation of the individual mechanisms of the informational regulation of a homeostasis that have a direct connection with lymphatic system, their dynamic consequence at the level of the entire organism and individual organs at the cellular level.. In the presented diagnostic package there are also used algorithms of interpretation of functional condition in the insight and conception of the doctors of antiquity (Tibet and China) that permits to correlate the informational factor of medicinal action the most adequately by taking into account their knowledge about healing properties of natural remedies (man-in-yan mode).

Using of symmetrical leads allows to conduct a functional diagnostics of vertebral column (the mode of “color diagrams – organs”, pic.6). (!) In this package is implemented a principle of individual selection and informational compliance of the natural remedies for treatment and prevention (medicinal plants, minerals, metals etc.) taking into consideration functional impairments of one or another organs or systems (mode of scanning – remedies). Using certain criteria of assessment of functional condition allows to define a parasitic, bacterial or viral burden as well as a propensity for oncological diseases.

pic.6

In this regimen there is also possible a prognostic estimation of the development of pathological impairments with the course of time (mode: absolute value, selection of coefficient).

The diagnostic criteria mentioned above widen the opportunities of use of functional diagnostics methods, allows to correlate the received results with findings of other methods that are used in the clinical practice with a purpose of early reveal of the existing pathology and its adequate diagnostics. This is especially important in practical medicine as the deviations at this level appear before the manifestation of the clinical symptoms.


Certificates

Hardware and software diagnostic complex (HSDC) “Intera” possesses:

  1. Certificate of state registration (R/N 3277/2004 from 10.30.2009).Print version.
  2. Certificate of state registration (State Department of medicines and products of medical assignment of Ministry of Health of Ukraine, R/N 3277/2004 from 10.01.2004).
  3. Certificate of conformance confirmed by Polish test and certification centre (Polskie Centrum Badan I Certyfikacji S.A., Certyfikat Zgodnosci Nr Z/13/14/04/BT z 01.06.2004).
  4. Software  is protected by copyright (State Department of intellectual property of Ministry of education and science of Ukraine, Certificate of registration #10411 from 30.06.2004).